Description

Description

Thermal Plate Recorder

Semi automatic thermal CTP recorder

The world’s No.1 CtP manufacturer, Dainippon Screen, presents a new, compact model that features everything you need to create a fully digital platemaking workflow. The PlateRite 8600MII is a semi automatic thermal CtP recorder that combines Screen’s unique external drum technology with high-precision optics to enable timely, high-quality plate output. When you use CtP, there is no need for complex processing and intermediate steps such as outputting layout data to film or exposing plates using film, which makes processing much simpler than the traditional platemaking methods of the past. The use of CtP also frees you from concerns about paste-up errors and foreign-matter contamination, while contributing to increased efficiency in both the platemaking and printing processes. Best of all, CtP output produces sharper halftone dots than traditional platemaking methods, and therefore dramatically improves printing quality.

Screen Platerite 8600MII Specifications

Product Name PlateRite 8600MII-S PlateRite 8600MII-E
Model Name PT-R8600MII-S PT-R8600MII-E
Recording system External drum
Light source 64-channel laser diodes 32-channel laser diodes

 

Plate size Maximum 1,060 x 830 mm (41.7″ x 32.6″); Minimum 450 x 370 mm (17.8″ x 14.6″)
Exposure size Maximum 1,060 x 806 mm (41.7″ x 31.7″)
[ Maximum 1,060 x 806 mm (41.7″ x 31.7″) at 900rpm; Maximum 1,060 x 810mm (41.7″ x 31.8″) at 600rpm ]
Plate Thermal aluminum plate
Plate thickness 0.15 to 0.3 mm (6 to 11.8 mil)
Resolutions 1,200/2,400/2,540 dpi*1
Repeatability ± 5 µm*2
Productivity 20 plates/hr (1,030 x 800 mm/40.5″ x 31.4″ plates) at 2,400 dpi*3 *4 13 plates/hr (1,030 x 800 mm/40.5″ x 31.4″ plates) at 2,400 dpi*3 *4
Interface F-PIF
Plate transport Semiautomatic loading
Dimensions (W x D x H) Main unit: 2,500 x 1,120 x 1,320 mm (98.5″ x 44.1″ x 52″)
Weight Main unit: 880 kg (1,930 lb)
Power requirements Main unit: Single phase 200 V to 240 V, 30A, 4.0 kW
Environment Recommended: 21 to 25°C (69.8 to 77°F); Required: 18 to 26°C (64.4 to 78.8°F); Relative humidity: 40 to 70% (no condensation)
Applicable standard Conform to IEC 60204-1, 60825-1